By the WY&G, Inc. team: licensed HVAC contractor, CSLB C-20 #1044922, over 25 years and thousands of customers in the Santa Clarita Valley and Orange County.
The five minute check
- Batteries. Blank, dim or frozen screen? That's the first suspect. Most wall thermostats take two AA or AAA cells. Use new ones, not the pair out of the TV remote.
- Set it clearly. Mode on Heat, fan on Auto, set point 4 or 5 degrees above the room temperature on the screen. A thermostat sitting one degree above the room will just sit there.
- Breaker. Find the one labeled furnace, heater or FAU and look closely. A tripped breaker can sit almost straight. Reset it once.
- The furnace switch. It looks like a plain light switch, usually on a wall or a joist right next to the furnace in the attic or the garage. Painters, insulation crews and curious kids turn it off.
- The door panel. If the furnace cover isn't seated, a safety switch keeps the unit from running at all. Push it in until it sits flush and the latch holds.
Give it a few minutes after each change. Most furnaces run the small inducer fan and wait before the burners light.
Read what happens when you raise the set point
- Screen blank, nothing at all. Batteries. On a thermostat powered from the furnace, it can also be the low voltage fuse on the control board, or the furnace has no power.
- Screen on, no sound from the furnace. Either the call isn't reaching the furnace, or the furnace has no power. This is the case where the thermostat or its wire really is the likely cause.
- Screen on, the furnace starts and then stops. The call is fine, so it's a furnace problem: flame sensor, igniter, pressure switch. See what short cycling timing tells you.
- Fan blows, air is cold. The burners aren't lighting or keep dropping out. See furnace blowing cold air.
- Heat runs but never reaches the number. Usually not the thermostat. Think airflow, duct leaks, or a system working against a cold night.
- The temperature on the screen is clearly wrong. A thermostat in afternoon sun, above a lamp, or on a wall with a draft behind it reads the wall, not the room.
Smart thermostats in Saugus tract homes
Most of Seco Canyon, Bouquet Canyon and the older Saugus tracts went up in the 70s, 80s and 90s with the furnace in the attic and four or five thermostat wires run down to the hallway. Newer neighborhoods like Skyline Ranch were wired for modern equipment from the start. That difference is behind most of the smart thermostat calls we get:
- No common wire. Older runs often have no C wire. Some smart thermostats then borrow power through the heat circuit, and the symptoms are strange: the furnace starts on its own, won't start when asked, or the thermostat keeps rebooting. See smart thermostats.
- Wires on the wrong terminals. Whoever changed the thermostat before you may have guessed. Heat pump homes get the O and B terminals crossed and end up with cool air when they ask for heat.
- One brittle wire in the attic. Thirty summers of attic heat make thermostat wire stiff. It breaks at a staple or at the furnace board, and the thermostat looks dead for no reason at all.
- A thermostat that never fit the system. Two stage furnaces, heat pumps and zoned systems need the right model and the right setup, not whatever was on the shelf.
Why these calls come on the first cold Bouquet Canyon nights
Saugus sits right up against the canyons, and cold air slides down Bouquet and Seco Canyon after sunset. A 72 degree afternoon becomes a 40 degree night, and that's the first time since spring anybody asks the furnace for anything. The thermostat batteries have been dying quietly since July. The furnace switch has been off since somebody worked in the attic in August. Nothing broke last night. It just finally got asked.
That's also why a healthy thermostat gets blamed. Before you buy a new one, go through the five checks. We would rather you spend nothing than spend it on the wrong part.
What a technician checks, and what you should leave alone
On a no heat call where the thermostat looks dead, we work from the thermostat back:
- Voltage at the thermostat terminals, to see whether the furnace is feeding it at all.
- A heat call made right at the furnace board. If the furnace fires with the thermostat out of the picture, the problem is the thermostat or the wire.
- The low voltage fuse and the transformer on the control board.
- The whole safety chain: door switch, limit switch, pressure switch, rollout switch. Any one of them open looks like nothing is happening.
- The thermostat wire end to end, and whether the thermostat is configured for the equipment it's actually wired to.
Leave the furnace panels, the gas valve and the wiring to a technician. And the rule that comes before everything: if you smell gas, don't touch a switch or the thermostat. Leave the house and call SoCalGas or 911 from outside. If a CO alarm sounds, everyone out, then 911. See carbon monoxide and your furnace.
Replace the thermostat, or fix the furnace?
A thermostat is worth replacing when the screen is unreadable, the buttons don't respond, it reads the room several degrees off, or it's an old mercury unit that can't control modern equipment. It is not worth replacing just because the furnace quit, and swapping it won't fix a dirty flame sensor or a cracked heat exchanger. What drives the price on a thermostat job is the model you choose, whether a common wire has to be pulled from the attic, and whether the system is single stage, two stage, heat pump or zoned. We tell you which of those applies before anything gets ordered. See furnace repair or replacement if the furnace itself is the question.
Heating repair in Saugus
WY&G is a licensed HVAC contractor (CSLB C-20 #1044922) based in Santa Clarita, with over 25 years in the Santa Clarita Valley. Attic furnaces and hallway thermostats in Saugus are ordinary winter work for us, and most no heat calls get handled the same day. See heater repair in Saugus, AC and heating in Saugus and furnace repair.
Call (661) 250-6056 or book online.